CN 51-1686/N

基于μPMU的含DG配电网故障区段定位方法

Fault Section Location Method for Distribution Networks with Distributed Generation Based on μPMUs

  • 摘要: 分布式电源(DG)的大量接入使得现有配电网故障定位方法难以完全适用。为此,提出一种基于微型同步相量测量单元(μPMU)的含分布式电源配电网的故障区段定位方法。首先,围绕运行经济性、故障可观性及定位需求,以总配置成本最低为目标,开展μPMU配置位置与数量的优化。然后,依据配电网拓扑模型将故障域划分为DG区域和非DG区域:对于DG区域故障,采用相角差值法进行判定并直接输出DG区段定位结果;对于非DG区域故障,先依据电压突变值初步圈定疑似故障域,再结合双端正序电压分布特性并采用单端阻抗法遍历搜索以获取精准的故障区段。最后,基于PSCAD/EMTDC仿真平台,采用IEEE33节点配电网模型验证该方法的可行性和有效性。该方法在智能配电网的故障监测和保护领域具有广阔的应用前景。

     

    Abstract: The large-scale integration of distributed generation (DG) limits the applicability of existing fault location methods in distribution networks. To address this issue, this paper proposes a fault section location method based on micro-synchrophasor measurement units (μPMUs) for distribution networks with DGs. First, the placement and number of μPMUs were optimized to minimize the total configuration cost while accounting for operational economy, fault observability, and fault location requirements. Then, based on the distribution network topology model, the fault domain was divided into DG and non-DG regions. For faults in DG regions, the phase-angle difference method was used to identify the faults, and the location of the faulty DG section was reported directly. For faults in non-DG regions, the suspected fault region was first preliminarily identified based on abrupt voltage changes. Subsequently, the precise fault section was determined through an exhaustive search using the single-ended impedance method in combination with the distribution characteristics of positive-sequence voltages at both ends. Finally, the feasibility and effectiveness of the proposed method are verified using the IEEE 33-bus distribution network model on the PSCAD/EMTDC simulation platform. The proposed method has broad application prospects in fault monitoring and protection for smart distribution networks.

     

/

返回文章
返回